It is mainly used for the detection of torsion and mechanical properties of materials and finished products at room temperature, as well as for the torsion failure of materials and finished products. The test specimen is installed between adjustable clamping fixtures, which can be used to test the torsion mechanical properties of different tested specimens. The test machine uses computer control operation, and the software synchronously displays the curves of torque - time, twist angle - time, torque - twist angle, torque - angle and so on. The parameters such as angle, torque and torque peak are displayed in real time, and the test results can be stored and printed.
Implementation standard: GB/T 10128, "torsion test method for metallic materials at room temperature", JJG 269 "verification regulation for torsion testing machine".
Torque range: 0 ~ 200Nm
Torque measurement range: 2Nm-200Nm;
Minimum reading value of torque: 0.01Nm
The resolution of the test torque is 1/ + 300000
Relative error value - torque: less than 1% (forward and reverse direction of two)
The torque repeatability of the relative error is less than or equal to 1%: (forward and reverse direction of two)
Rotation angle measurement range 0-10000 degree
Relative error value - angle: less than 1% (forward and reverse direction of two)
Twist angle (small angle measurement) shows minimum resolution: 0.0001 degrees.
The minimum reading value of computer controlled material torsion testing machine is 0.01 degrees.
The test speed is 0.05-720 degrees /min (before yielding, it should be at 3 degrees /min-30 degrees /min, and yield is not greater than 720 degree /min).
The reverse speed relative indication error: less than 1% (forward and reverse direction of two)
The reverse speed indication repeatability error: less than 1%
The distance between the power plate and the torque plate is 0 ~ 300mm.
Two - chuck concentricity: more than Phi 0.3mm
• sample clamping diameter: standard sample (round specimen diameter 10, gauge spacing 50mm, 100mm).
Power supply: AC 220V + 10%, 50Hz;
The way of sample clamping is to provide a fixture according to user's sample.
Level of test: Grade 1
Net mainframe size (mm): about 1050*430*550mm
Mainframe weight (kg): about 200